U-TUBED CORIOLIS MASS FLOW METER (ALCM-UT)
Specifications
Type:
U Tube Coriolis
Sizes:
1"-12" (40-300mm)
Accuracy:
± 0.1, 0.15, 0.2 and 0.5% of reading
Process Temperature:
-40-662°F (-30-350°C)
Liquid requirement:
Higher flows, traditional shape with water-cut measurement
Process Connection:
Flanged (ANSI, DIN, JIS, Sanitary)
Application:
Legacy replacement for large existing install base of U-tube meters, Oil & Gas
Process Medium:
Liquids
SmartMeasurement’s ALCM-UT Coriolis flow meters utilize two tubes formed into a U-shaped geometry in a parallel arrangement, which are vibrated at their resonant frequency by coils. Any mass flow passing through the tubes will generate Coriolis forces, which are created whenever a mass moves radially in a rotating system. These forces have opposite effects on the inlet and outlet sides, deforming each tube to a small degree.
How Do U-Tubed Coriolis Mass Flow Meters Work?
The excursion of the tubes is detected by sensors located at the meter inlet and outlet, and is measured as a time delay, or phase shift. The phase shift between the rotational frequencies of both tubes is directly proportional to the mass flow rate.The resonant frequency of the U-tubed Coriolis mass flow meter’s tubes changes in proportion to the density of the fluid media. This effect allows for the measurement of media density.
Using only one sensor, both density and temperature measurements can be collected, as the extent of deformation of the pipes is temperature-dependent. Therefore, the temperature is measured for compensation purposes. Using only one instrument, values including mass flow, density, and temperature can be measured.
Features
- Suitable for aggressive & contaminated media
- Measurement of mass flow, density, temperature & volume flow
- Measurement & display of percent water-cut for oil/water mixtures
- Excellent purging & sterilization qualities thanks to a construction that is free of dead-spots
- High rotation frequency & well-balanced measuring tubes
- Operating temperatures up to 575°F (300°C)
- Individual 8-point calibration including NIST-traceable report
- Optional EX protection
Flow Range: | 1,500~1,000,000 kg/hr |
Process Connections: | Flanged (ANSI, DIN, Tri-Clamp®) |
Line Sizes: | 1¼”~8” (40-200 mm) |
Process temperature: | -58~392 °F (-50~200 °C) -std |
Tube geometry: | U-Tube |
Accuracy: | ±0.5% of reading(std), 0.2% or 0.15% (opt) |
Repeatability: | ±0.075% of reading |
Frequency: | 10-2000 Hz |
Engineering Units (Mass): | kg, lb, ton |
Display: | Color Graphic OLED |
Engineering Units (Temp.): | °C, °F |
Engineering Units: (Volume): | m³, Liter, US Gallon, Imperial Gallon |
Zero Stability: | 0.1% full-scale |
Ambient temperature: | -5~312 °F (-20~55 °C) |
Zero Drift (%FS / °C): | 0.005 |
Max Working Pressure: | 360 psig (2.5MPa) std, 930 psig optional |
Measuring Tube Mat’l: | SS per DIN1.4571 (AISI 316Ti) standard |
Power Supply: | 24 VDC, ± 20%; 86~260VAC,50~60Hz |
Housing Material: | SS #304 |
Outputs: | 4-20 mA, 0-10 kHz pulse, RS485 |
Power Consumption: | Less than 6W |
Density Measuring Range: | 12.5-125lb/ft³ (0.2~2.0 g/cc) |
Density Accuracy: | ±0.06 b/ft³ (0.001 g/cc) |
Water Cut Measuring Range: | 0-100% |
Water Cut Accuracy: | ±0.1% of range |
Temperature Accuracy: | up to ±1 °C |
Refer to the link for more details: https://www.smartmeasurement.com/u-tubed-coriolis-mass-flow-meter/
Inquiry - U-TUBED CORIOLIS MASS FLOW METER (ALCM-UT)