MINITRAC 31

MINITRAC 31

Share:


MINITRAC 31

Specifications

Accuracy:
0.1 %

Process Temperature:
-40 ... 60 °C

Materials, wetted parts:
No wetted material

Protection rating:
IP66/IP67

Output:
- Profibus PA
- Foundation Fieldbus
- 4 … 20 mA/HART - four-wire

Ambient temperature:
-40 ... 60 °C

Display & adjustment:
- PLICSCOM
- PC, PACTware and DTM
- HART-Communicator
- Software (e. g. AMS, PDM)

Seal Material:
no media contact

Housing Material:
- Aluminium
- Stainless steel (precision casting)

Approvals:
- ATEX / Europe
- CSA / Canada
- FM / USA
- EAC (GOST) / Belarus
- EAC (GOST) / Russia
- IEC / worldwide
- NEPSI / China
- INMETRO / Brazil

Explosion Protection:
- Intrinsic safety "i"
- Flameproof enclosure "d"
- Dust explosion protection through housing "t"

Overfill protection:
WHG

SIL qualification:
SIL2

Indication:
- Display/adjustment module PLICSCOM
- VEGADIS 81
- VEGADIS 82


Radiometric sensor for density measurement

Point detector

Application area

The MINITRAC 31 is a radiation-based sensor for non-contact density measurement of liquids and bulk solids. The MINITRAC 31 determines the density contactlessly from outside through pipelines or the vessel wall. Through its compact design it is ideal for mounting in positions hardly to access and in narrow space applications.

Advantages

  • Simple retrofitting during production processes
  • High plant availability through non-contact measurement
  • Exact measuring results independent of the process conditions

Technical data

Version sensor with integrated NaI detector
Mounting from outside on pipelines or the vessel
Reproducibility +/- 0,1 %
SIL qualification optionally up to SIL2

Refer to the link for more details: https://www.vega.com/en/home_de/products/product-catalog/density/radiation-based/minitrac-31

 Inquiry - MINITRAC 31