VEGACAL 65 - for measurement of bulk solids & non-conductive liquids
VEGACAL 65 - for measurement of bulk solids & non-conductive liquids
Capacitive cable probe for continuous level measurement
Cable probe, partly PTFE insulated
Application area
For measurement of bulk solids and can also be used in non-conductive liquids such as oil. A full/empty adjustment is necessary for setup.
The VEGACAL 65 is a level sensor for use in all industries. The partly insulated probe is ideal for the measurement of bulk solids and can be also used in non-conductive liquids such as for example oil. The proven mechanical construction offers high functional safety.
Your benefit
- High flexibility through shortenable probe
- Long lifetime and low maintenance requirement through robust mechanical construction
- Maximum utilization of the vessel because measurement over the complete probe length
Technical Specifications | |
Measuring range - Distance | 32 m |
Process temperature | -50 ... 200 °C |
Process pressure | -1 ... 64 bar |
Version | Partly insulated cable of steel, 316L, PTFE, PA |
Threaded connection | ≥ G1, ≥ 1 NPT |
Flange connection | ≥ DN50, ≥ 2'' |
Housing material |
|
Output | Profibus PA, Foundation Fieldbus, 4 … 20 mA/HART - two-wire |
Ambient temperature | -40 ... 80 °C |
Approvals | ATEX, CSA, FM, EAC (GOST), IEC, KOSHA, NEPSI, UKR Sepro, INMETRO, Explosion protection, Ship, Overfill protection, SIL2 |
Refer to the link for more information: https://www.vega.com/en/home_de/products/product-catalog/level/capacitive/vegacal-65