Area Velocity Open Channel Ultrasonic Meter (ALSONIC-AVM)

Area Velocity Open Channel Ultrasonic Meter (ALSONIC-AVM)
Area Velocity Open Channel Ultrasonic Meter (ALSONIC-AVM)
Area Velocity Open Channel Ultrasonic Meter (ALSONIC-AVM)
Area Velocity Open Channel Ultrasonic Meter (ALSONIC-AVM)

Share:


Area Velocity Open Channel Ultrasonic Meter (ALSONIC-AVM)

Specifications

Sizes:
Sizes 3'-130' (1-40 m)

Accuracy:
0.5-1%

Temperature:
Ambient, transducers can withstand temperatures of 248°F (120°C)

Application:
Open channel; clean and dirty water

Styles:
Installation channel walls

Medium:
Clean or dirty channels, rivers etc.

Function:
Two or four channels, graphic display, datalogger, analog/ digital inputs & outputs


SmartMeasurement’s ALSONIC-AVM system is an area-velocity meter that is used in conjunction with a user-supplied level transmitter to measure flow rates in open channels. The ALSONIC-AVM consists of an advanced DSP-based flow computer and four transducers. It uses the transit time difference of ultrasonic sound pulses to measure the open channel flow velocity. The ultrasonic pulses are transmitted upstream and downstream across the channel at an angle α between the flow direction and the sonic wave path, with the difference in the sonic wave’s transit time being directly proportional to the liquid velocity. 

The ALSONIC-AVM may be used in rectangular, circular, trapezoidal or other shaped channels. Since the transducers create almost no restriction, virtually no head loss is created. The advanced DSP-based flow computer with cross-correlation and FFT technology allows this system to work in the most difficult applications, including those involving liquids with high concentrations of suspended solids & air or a large noise component.

Alsonic-Avm

ALSONIC AVM TRANSIT TIME

  • Installation channel walls
  • Clean or dirty channels, rivers etc.
  • Sizes 3'-130' (1-40 m)
  • Ambient, transducers can withstand temperatures of 248°F (120°C)
  • 0.5-1%
  • Channel walls with multi-transducers four paths-cross, Flow & Level (separate), Alignment using laser pointer
  • Two or four channels, graphic display, datalogger,analog/ digital inputs & outputs
  • Open channel; clean and dirty water
     

Alsonic-Avm
 

ALSONIC AVM SEWER TRANSIT TIME

  • Installation fitted inside sewer line
  • Clean or dirty Sewers
  • Sizes 6''-48" (100-1200 m)
  • Ambient, transducers can withstand temperatures of 248°F (120°C)
  • 0.5-1%
  • Fitted inside sewer line
  • Three or four channels, graphic display, datalogger, analog/ digital inputs & outputs
  • Clean or dirty sewers
Alsonic Davm Open Channel Flow Meter

ALSONIC DAVM DOPPLER

  • Installation bottom of channel
  • Wastewater, sewers, dirty liquids ≥ 1% ≤40% particulates
  • Sizes 6"-240" (150-6000 mm)
  • Ambient, transducers can withstand temperatures of 248°F (120°C)
  • 2-5%
  • Single transducer with both flow and level with mounting ring at bottom of channel
  • One transducer for both flow and level. Available in fixed and portable system
  • Economic open channel monitoring, mainly used for sewers and surveying
Measuring Principle: Ultrasonic transit-time differential, 4-path
Max pass length: 2.46’ (750 mm)
Min pass length: 46’ (14m)
Channel Geometrics: RectangularCircularTrapezoidalOther (Consult SMC factory)
Velocity Range: ±0.03~40 feet/sec (±0.01~12m/s)
Accuracy: ±2.0% of reading
Flow Rate: 4½ digit
Repeatability: ±1.0% of reading
Engineering Units: m³, Liter, US Gallon, Imperial Gallon, Millon Gallon, Cubic Feet, US Barrels, Imperial Barrels, Oil Barrel
Totalizer: 10-digit, Positive, Negative & Net values
Turn down ratio: 1000:1
Response Time: Less than one second
Keypad: 16 Key with tactile action
Ambient temperature: -4~140°F (-20~60°C)
Resolution: 0.003 feet/sec (0.001 m/s)
Data logger: 32 Mbytes; up to 200,000 fields
Weight: See data sheet
Power Supply: 90~250 VAC, 50/60 Hz
Outputs: 4-20 mADC, relay, RS-232C
Communication: RS-232
Input: 4-20 mADC
Max Cable Length: 650′ (200m)
Alarm: Two relays for total/hi flow
Data storage: EPROM storage up to 10 years
Power Consumption: Less than 20 W
Dimensions: See data sheet
Enclosure Mounting: Wall mount
Transducer Materials: Stainless steel #316 (housing & sphere)Polycarbonate (lens)
Protection (converter): NEMA 4 (IP 65)
Protection (transducers): NEMA 6P (IP68) – Submersible

Refer here for more details: https://www.smartmeasurement.com/alsonic-avm/
 

 Inquiry - Area Velocity Open Channel Ultrasonic Meter (ALSONIC-AVM)