Level of oil / water recovery reactor

Level of oil / water recovery reactor

Share:


Level of oil / water recovery reactor

Level of oil / water recovery reactor

 

 

Process data

Measuring point
Reactor
Measuring range up to
6 m
Medium
Oil/water mixture
Process temperature
0 ... +50° C
Special challenges
Changing oil and water mixtures, emulsions, vapours, condensation, tank internals, agitated surfaces

Application

At a recycling company, oil sludge, oil/water mixtures and emulsions from many industrial processes are collected and treated. The objective is to separate the oil and water for recovery, purification and reuse. This process takes place in several steps. Firstly the oil/water mixture is centrifuged, hydrogen peroxide is added and mixed in a stirring reactor, then finally it is centrifuged again. Continuous level measurement is required in the reactor stage to enable automated operation. Its very Important for there to be an absolutely reliable and accurate measurement even at low liquid levels, right down to the vessel bottom. Inside the reactor there are baffles and an agitator. During the process sometimes heavy vapours are given off along with condensation, the liquid density also changes. Also note how close to the edge the mounting point is.

Your benefit

Reliable
Reliable function, even with changing liquid properties, vapours, internals and agitators
Cost effective
Inexpensive integration into the reactor vessel, no modifications required
User friendly
Contactless sensor, measuring point easily accessible
 


 Inquiry - Level of oil / water recovery reactor