Level and pressure measurement in the distillation unit

Level and pressure measurement in the distillation unit

Share:


Level and pressure measurement in the distillation unit

Distillation column

Level and pressure measurement in the distillation unit

Level and pressure measurement in the distillation unit
 

Process data

Measuring task
Level and pressure measurement
Measuring point
Column
Measuring range up to
6 m
Medium
Hydrocarbon
Process temperature
+260 ... +400 °C
Process pressure
+0.5 ... +4 bar
Special challenges
Very high temperature, viscous process liquid

Application

The heavy, highly viscous process material and extreme temperature are located in the bottom part of the distillation. For level control of residual feeds, a non-contact measurement is essential for reliability. Monitoring head space pressure at the upper end of refinery columns is important to ensure that the process is operating under ideal conditions.

Your benefit

Reliable
Precise measurement results even in extreme environments
Cost effective
Easy mounting reduces installation and maintenance costs
User friendly
Simple calibration even during running process
 